CHTCT - NAVY GRAY GELCOAT, 42847
- MSDS: CHTCT
- Manufacturer: NESTE POLYESTER
- Product Name: NAVY GRAY GELCOAT, 42847
- National Stock Number: 8030-00N087615
Product Identification
Product ID:NAVY GRAY GELCOAT, 42847
MSDS Date:09/19/1994
FSC:8030
NIIN:00N087615
Status Code:A
MSDS Number: CHTCT
Responsible Party
FORT SMITH, AR 72901
US
Emergency Phone: 800-424-9300 (CHEMTREC)
Info Phone: 501-646-7865
Preparer: BK
Cage: JO113
Contractor
Telephone: 501-646-7865
Cage: JO113
Ingredients
METHYL METHACRYLATE (SARA 313) (CERCLA)
CAS: 80-62-6
RTECS: OZ5075000
Fraction By Weight: <5%
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
STYRENE MONOMER (SARA 313)
CAS: 100-42-5
RTECS: WL3675000
Fraction By Weight: 32.72%
OSHA PEL 100 PPM
ACGIH TLV: 50 PPM/100 STEL, S
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
0.021
RTECS: 9999999VO
OSHA PEL N/K
ACGIH TLV: N/K
PARTICULATE & GAS & VAP. IN CONFINED AREAS USE
RTECS: 9999999ZZ
ALSO BE NEC IN ANY LATER MANUFACTURING OPERATIONS IN
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: VAPS MAY CAUSE IRRIT OF EYES,
NOSE, THROAT, UPPER RESP TRACT, MUC MEMBS, & SKIN. CHRONIC: RPTS
HAVE ASSOC RPTD & PRLNG OCCUP OVEREXP TO SOLVS W/PERM BRAIN & NERV
SYS DMG. INTENTIONAL MISUSE BY DELIB CONCENTRATING & INHALING
CONTENTSMAY BE HARMFUL/FATAL.
Explanation of Carcinogenicity:STYRENE: IARC MONOGRAPHS, SUPPLEMENT,
VOLUME 7, PAGE 345, 1987: GROUP 2B. ANIMAL: NERVOUS SYSTEM.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES: FLUSH W/LUKE WARM WATER FOR AT LEAST 15 MIN. SEEK MD
IMMED. SKIN: FLUSH WASH W/COPIOUS AMTS OF LUKE WARM WATER. REMOVE
CONTAM CLTHG PROMPTLY. WASH THORO W/SOAP & WATER. INHAL: REMOVE TO
FRESH AI R. RESTORE BRTHG IF REQUIRED. CONT MD IMMED. INGEST: RINSE
MOUTH IMMED. GIVE 6-8 OUNCES OF LIQ. (NEVER GIVE ANYTHING BY MOUTH
TO UNCON PERS.) DO NOT INDUCE VOMIT UNLESS ADVISED BY MD. CONT MD
IMMED.
Fire Fighting
Flash Point Method:TCC
Flash Point:83.0F,28.3C
Lower Limits:1.1%
Upper Limits:12.5%
Extinguishing Media:WATER, CARBON DIOXIDE, DRY CHEMICAL, WATER FOG.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:KEEP CONTRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPKS, & OPEN FLAME. VAPS MAY BE HVR/AIR & MAY
TRAVEL ALONG GROUND BEFORE IGNIT/FLASHING BACK (SUP DAT)
Accidental Release
Spill Release Procedures:STAY UPWIND & AWAY FROM SPILL UNLESS WEARING
APPROP PROT EQUIP. STOP &/OR CONTAIN DISCHARGE IF SAFE. KEEP ALL
SOURCES OF IGNIT AWAY. VENT AREA. USE NON-SPKG TOOLS FOR CLEANUP.
COVER W/INERT MATL TO RE DUCE FUMES. KEEP OUT OF DRAINS,
SEWERS,(SUP DAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT BREATHE VAPS/SPRAY MISTS. USE
I/A/W GOOD INDUS WORKPLACE PRACT. AVOID UNNEC CONT. STORE IN DRY
AREA AWAY FROM EXCESS HEAT. FOR INDUS USE ONLY.
Other Precautions:PERS SHOULD AVOID INHAL OF VAPS. AVOID PERS CONT.
SHOULD CONT BE MADE, REMOVE SATURATED CLTHG & FLUSH AFFECTED SKIN
AREAS W/WATER. CONTRS MAY BE HAZ WHEN EMPTIED. SINCE EMPTIED CONTRS
RETAIN PROD RESI DUES (VAP, LIQ, &/OR SOLID), (SUP DAT)
Exposure Controls
Respiratory Protection:IN OUTDOOR/OPEN AREAS USE NIOSH APPRVD MECH
FILTER RESP TO REMOVE SOLID AIRBORNE PARTICLES OF OVERSPRAY DURING
SPRAY APPLICATION. IN RESTRICTED VENT AREAS USE NIOSH APPRVD
CHEM-MECH FILTERS DESIGNED T O REMOVE COMBINATION OF (ING 4)
Ventilation:USE VENTILATION AS REQUIRED TO CONTROL VAPOR
CONCENTRATIONS. AVOID PROLONGED OR REPEATED BREATHING OF VAPORS.
Protective Gloves:NATRL RUBBER, NEOPRENE, BUNA N/NITRILE.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA . WEAR APRON TO AVOID SKIN CONTACT.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
EXPLO HAZ: TO VAP SOURCE. KEEP WELDING/CUTTING EQUIP AWAY FROM PROD.
SPILL PROC: OR WATERWAYS. CONT FIRE AUTH. NOTIFY LOC HLTH &
POLLUTION CTL AGENCIES. CALL SPILL RESPONSE TEAMS IF LGE SPILL.
OTHER P REC: ALL HAZ PREC GIVEN IN MSDS MUST BEOBSERVED.
Chemical Properties
Boiling Pt:B.P. Text:>214F,>101C
Vapor Pres:29 @ 68F
Vapor Density:HVR/AIR
Spec Gravity:1.24
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:INSOLUBLE
Appearance and Odor:WHITE LIQUID WITH AROMATIC ODOR
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS, PEROXIDES, AND OTHER OXIDIZING AGENTS, ORGANIC METAL
SOAPS.
Stability Condition to Avoid:AVOID EXPOSURE TO SPARKS, OPEN FLAME, HOT
SURFACES, AND ALL SOURCES OF HEAT AND IGNITION.
Hazardous Decomposition Products:THERMAL DECOMPOSITION MAY PRODUCE
TOXIC OXIDES OF CARBON AND/OR NITROGEN.
Disposal
Waste Disposal Methods:DO NOT FLUSH TO SEWER, WATERSHED, OR WATERWAY.
DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS.
DO NOT INCINERATE CLOSED CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.